SERVICE MANUAL (Basic Information)
CMH1822 / KMH0922 ( 2)
SPLIT SYSTEM AIR CONDITIONER
8526481017400 REFERENCE NO. WM700700
W
Indoor Unit Outdoor Unit
CMH1822
KMH0922
92-144 S/M (Basic) 00.12.13 10:32 AM ページ A
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL (Basic Information)CMH1822 / KMH0922 (✕ 2)SPLIT SYSTEM AIR CONDITIONER8526481017400 REFERENCE NO. WM–700700WIndoor Unit Outdoor UnitCMH

Strona 2

4. COOLING CAPACITY230VCMH1822 / KMH0922 (×1)5WM– 700700TC: Total Cooling Capacity (BTU/H)SHC: Sensible Heat Capacity (BTU/H)kW: Compressor Input (kW)

Strona 3 - SERVICE MANUAL

6WM– 700700208VCMH1822 / KMH0922 (×1)TC: Total Cooling Capacity (BTU/H)SHC: Sensible Heat Capacity (BTU/H)kW: Compressor Input (kW)Remarks: Rating con

Strona 4 - Please Read Before Starting

7WM– 7007005. HEATING CAPACITY1 Phase 60Hz 230V Model Name: CMH1822 / KMH0922 (×1)Indoor Entering Air Temperature 70°FTemperature of Air Entering

Strona 5 - Table of Contents

8WM– 7007001 Phase 60Hz 208V Model Name: CMH1822 / KMH0922 (×1)Indoor Entering Air Temperature 70°FTemperature of Air Entering Outdoor Coil(°F D.B

Strona 6 - 1. OPERATING RANGE

Heat exchangerNarrow tubeO. D.1/4"(6.35mm)Wide tubeO.D.3/8"(9.52mm)ServicevalveMufflerAccumulatorCompressor AReversingvalveService valveDehy

Strona 7 - 2. SPECIFICATIONS

10WM– 7007007. ELECTRICAL DATA● Electrical CharacteristicsCMH1822 / KMH0922 (×1)Remarks: Rating conditions are:Cooling: Outside air temperature 95°F

Strona 8 - Applicable Indoor Unit

11WM– 700700● Electrical Wiring DiagramOutdoor Unit: CMH1822CMASCRBLKREDCompressormotor APTC. AWHTBLK WHTOLR. ACMBRCSREDCompressormotor BWHTOLR. BBL

Strona 9 - 3. DIMENSIONAL DATA

12WM– 700700Indoor Unit: KMH0922112121112122255443311554433112266Thermistor2PSupplyCONTROLLERRemotecontrolswitchFan motorFM231212BRNPNKGRYYELWHTVLTGR

Strona 10 - 4. COOLING CAPACITY

For parts or service contactSFS Corporation: 1200 West Artesia Blvd., Compton, California 90220Printed in U.S.A.CORPORATION1991/Nov./12MSANYO Canada I

Strona 11 - CMH1822 / KMH0922 (×1)

92-144 S/M (Basic) 00.12.13 10:32 AM ページ B

Strona 12 - 5. HEATING CAPACITY

iiWM– 700700SERVICE MANUALCMH1822 / KMH0922 (×2)(Basic Information)92-144 S/M (Basic) 00.12.13 10:32 AM ページ ii

Strona 13 - Heat-pump capacity

WM– 700700IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or service p

Strona 14 - 6. REFRIGERANT FLOW DIAGRAM

Table of ContentsPage1. OPERATING RANGE...

Strona 15 - 7. ELECTRICAL DATA

1WM– 7007001. OPERATING RANGETemperature Indoor Air Intake Temp. Outdoor Air Intake Temp.Maximum 95°F DB / 71°F WB 115°F DBMinimum 67°F DB / 57°F WB 6

Strona 16 - ● Electrical Wiring Diagram

DATA SUBJECT TO CHANGE WITHOUT NOTICE.Remarks: Rating conditions are:Cooling: Outside air temperature 95°F DB/75°F WBIndoor unit entering air tempera

Strona 17 - Indoor Unit: KMH0922

3WM– 700700DATA SUBJECT TO CHANGE WITHOUT NOTICE.Remarks: Rating conditions are:Cooling: Outside air temperature 95°F DB/75°F WBIndoor unit entering

Strona 18 - H407/12M Printed in U.S.A

WM– 70070043. DIMENSIONAL DATAOutdoor Unit: CMH1822Indoor Unit: KMH0922O.D. 3/8" wide tubing service valve2-9/323-3/411-7/321-3/162-1/432-11/16