CM1972 (3-room multi unit)CM2472 (4-room multi unit)CM3172 (4-room multi unit)< Applicable Multi-Outdoor Units >INDOOR UNIT : XMS0972 & P
Indoor Unit XMS1272 & PNR-XS1872VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerant0.111711,9003.5Cooling230V Single-Phase 60Hz187 to 253Refrigeran
2A. Installing with in-wall junction box(1) Install the junction box (locally purchased) into the wall.(Figs. 2-a and 3)(2) Pass the wire harness thro
Fig. 8IndicatorWire harnessCeilingpanelTerminal coverClamps7P IND and 4P RCwiring connector5P FLAPwiring connectorClamping strapFLAPRCIND7P4P5P FLAPwi
4Fig. 9Fig. 10Fig. 11ON/OFFoperation button1 HR.TIMERbuttonNIGHT SETBACKbuttonACL (Reset)buttonSENSOR buttonOPERATION lampTIMER lampHIGH POWER lampREM
For Parts or Service Assistance please contact your local Sanyo HVAC Contractor or DistributorUnited States: SCS, HVAC SolutionsWeb: www.SanyoHVAC.com
Indoor Unit XMS1272 & PNR-XS1872VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerantCooling208V Single-Phase 60Hz187 to 253Refrigerant Tubing Connec
Indoor Unit XS1872 & PNR-XS1872VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerant0.152217,5005.15Cooling230V Single-Phase 60Hz187 to 253Refrigeran
Indoor Unit XS1872 & PNR-XS1872VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerant0.162217,5005.15Cooling208V Single-Phase 60Hz187 to 253Refrigeran
Indoor Unit (Body) XMS0972Indoor Unit (Panel) PNR-XS18722-2. Major Component Specifications2-2-1. Indoor UnitMP24ZN-12V ... 2Flap MotorType Stepping
Indoor Unit (Body) XMS1272Indoor Unit (Panel) PNR-XS1872MP24ZN-12V ... 2Flap MotorType Stepping MotorRating Model ... Q'tyCoil Resistance Ohm(Amb
Indoor Unit (Body) XS1872Indoor Unit (Panel) PNR-XS1872MP24ZN-12V ... 2Flap MotorType Stepping MotorRating Model ... Q'tyCoil Resistance Ohm(Ambi
2-3. Other Component Specifications Indoor Unit XMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS1872032 50 68 86 104 122 140
3. DIMENSIONAL DATAIndoor Unit XMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS18726-5/16 6-11/161-3/16 (30)4-19/321-25/321-
O.D. 3/8" (9.52 mm)O.D. 1/4" (6.35 mm)O.D. 1/2" (12.7 mm)O.D. 1/4" (6.35 mm)4. REFRIGERANT FLOW DIAGRAM4-1. Refrigerant Flow Dia
SAFETY PRECAUTIONSWarningBefore performing an overhaul, disconnect the power plug or power cable from the unit.Performing the work with the power supp
5. ELECTRICAL DATA5-1. Electric Wiring DiagramsIndoor Unit XMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS18728FA2-5250-469
6. MAINTENANCE6-1. Disassembly Procedure6-1-1. Remove the air intake grill.(1) Slide the 2 latches each to the corresponding arrow direction. (Fig
NOTE6-1-3. Remove the ceiling panel.(1) Open the clamp (4 locations) and remove the 2 lead wires from the clamps. (Fig. 6)(2) Remove the 4 screws fi
1236-1-4. Remove the indoor air temperature sensor.(1) Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperat
12 3(4) Disconnect the connector CN07 (DP 2P) in the power box. (Fig. 13) Remove a screw and disconnect the ground cable. (Fig. 13)(5) Disconnect t
For the removal of the following components, perform any work after removing the indoor unit (main body) from the ceiling. Main body lower section
6-1-7. Remove the heat exchanger sensor.(1) Remove the heat exchanger sensor from the sensor holder. (Fig. 19) 6-1-8. Remove the drain pump and floa
6-1-9. Remove the turbo fan and fan motor.(1) Remove a nut and remove the turbo fan. (Fig. 22)(2) Remove the 2 screws and 3 nuts, and remove the fan
Emergency operation SENSOR DRY During DRY operation, the system adjusts the room temperature and fan speed according to the conditions in the room, i
HIGH POWERNIGHT SETBACKLamp colorsTimer backupThis function acts to raise the power but keeps the AC system in the same operating mode.This function i
WarningIf refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite.If refrigerant gas leaks during the wo
Freeze preventionDuring COOL or DRY operation, freezing is detected and operation is stopped when the temperature of the indoor heat exchanger matches
< Clock display >Test run modeSelf-diagnostics mode8. TROUBLESHOOTING8-1. Precautions before Performing Inspection or RepairNOTEAfter checking
Since the indications cover various units, the corresponding parts listed below may not be present in some models.(1) Self-diagnostics LampsIndicat
(2) If the self-diagnostics function fails to operateCheck the indoor unit.Is the fuse blown?Replace the controller.Replace the circuitboard or the fu
(3) Serial Communication Error Identification ProcedureRefer to "Method of Self-Diagnostics" for the self-diagnostics procedure.(3-1) Condit
What is the latest self-diagnosis result ?Condition: E12Defect in the outdoor unitP. C. board.Condition: E01Defect or connection errorin the inter-uni
(3-2) Condition: E12Troubleshooting Serial Communication1. Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is
[Trouble symptom 3] Motor rotates for some time (several seconds), but then quickly stops, when the indoor unit operates.(There is trouble in the sys
8-5. Noise Malfunction and Electromagnetic InterferenceAn inverter A/C operates using pulse signal control and high frequencies. Therefore, it is sus
INSTRUCTION MANUALXMS0972 & PNR-XS1872XMS1272 & PNR-XS1872(OI-852-6-4181-141-00-0)APPENDIX AA-1
SAFETY PRECAUTIONSTABLE OF CONTENTS APPLICABLE MULTI-OUTDOOR UNITS1. OPERATING RANGE2. SPECIFICATIONS2-1. Unit Specifications 2-2. Major
XMS0972XMS1272COOL/DRY Model© SANYO 2009Pub. OI-85264181141000INSTRUCTION MANUALInverter-Controlled Split System Air ConditionerMODE D’EMPLOIClimatise
2FEATURESThis air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided b
3PRODUCT INFORMATIONIf you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbe
4NAMES OF PARTSThis illustration is based on the external view of a standard model.Consequently, the shape may differ from that of the air conditioner
5REMOTE CONTROL UNIT (DISPLAY)(1) Operation modeMILD DRY ...COOL...FAN ...
6REMOTE CONTROL UNITTransmitterWhen you press the buttons on the remote control unit, the mark appears in the display to transmit the setting changes
7SensorA temperature sensor inside the remote control unit senses the room temperature.(Cover closed)CLOCK buttonACL button (ALL CLEAR)Puts the remote
8USING THE REMOTE CONTROL UNITHOW TO INSTALL BATTERIES1. Slide the cover in the direction indicated by the arrow and remove it.2. Install two AAA alka
9OPERATION WITH THE REMOTE CONTROL UNIT1. Operation 2. Adjusting the Fan SpeedA. Automatic fan speedSimply set the FAN SPEED selector button to the
104. Night Setback ModeNight Setback Mode is used for saving energy.Press the NIGHT SETBACK button while operation. The mark appears in the display
APPENDIX D INSTRUCTION MANUAL (STK-RCS-7TWSUA)APPENDIX E INSTALLATION INSTRUCTIONS (STK-RCS-7TWSUA)...
111. How to set the present time(Example) To set to 10:30 pm. 2. How to set the OFF time(Example) To stop the air conditioner at 11:00 am. 3. How to
12USING THE 1-HOUR OFF TIMER1. 1-Hour OFF TimerThis function causes the unit to operate for one hour and then stop, regardless of whether the unit is
13OPERATION WITHOUT THE REMOTE CONTROL UNITIf you have lost the remote control unit or it has trouble, follow the steps below.When the air conditioner
14Air filterThe air filter collects dust and other particles from the air and should be cleaned once every 6 months.If the filter gets blocked, the ef
15TROUBLESHOOTINGIf your air conditioner does not work properly, first check the following points before requesting service. If it still does not work
INSTRUCTION MANUALXS1872 & PNR-XS1872(OI-852-6-4181-108-00-1)APPENDIX BA-2
XS1271XS1872COOL/DRY Model© SANYO 2009Pub. OI-85264181108001INSTRUCTION MANUALInverter-Controlled Split System Air ConditionerMODE D’EMPLOIClimatiseur
2FEATURESThis air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided b
3PRODUCT INFORMATIONIf you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbe
4NAMES OF PARTSThis illustration is based on the external view of a standard model.Consequently, the shape may differ from that of the air conditioner
APPLICABLE MULTI-OUTDOOR UNITSXMS0972 & PNR-XS1872XMS1272 & PNR-XS1872XS1872 & PNR-XS18723-RoomCM1972YESYESYES4-RoomCM2472YESYESYES4-R
5REMOTE CONTROL UNIT (DISPLAY)(1) Operation modeMILD DRY ...COOL...FAN ...
6REMOTE CONTROL UNITTransmitterWhen you press the buttons on the remote control unit, the mark appears in the display to transmit the setting changes
7SensorA temperature sensor inside the remote control unit senses the room temperature.(Cover closed)CLOCK buttonACL button (ALL CLEAR)Puts the remote
8USING THE REMOTE CONTROL UNITHOW TO INSTALL BATTERIES1. Slide the cover in the direction indicated by the arrow and remove it.2. Install two AAA alka
9OPERATION WITH THE REMOTE CONTROL UNIT1. Operation 2. Adjusting the Fan SpeedA. Automatic fan speedSimply set the FAN SPEED selector button to the
104. Night Setback ModeNight Setback Mode is used for saving energy.Press the NIGHT SETBACK button while operation. The mark appears in the display
111. How to set the present time(Example) To set to 10:30 pm. 2. How to set the OFF time(Example) To stop the air conditioner at 11:00 am. 3. How to
12USING THE 1-HOUR OFF TIMER1. 1-Hour OFF TimerThis function causes the unit to operate for one hour and then stop, regardless of whether the unit is
13OPERATION WITHOUT THE REMOTE CONTROL UNITIf you have lost the remote control unit or it has trouble, follow the steps below.When the air conditioner
14Air filterThe air filter collects dust and other particles from the air and should be cleaned once every 6 months.If the filter gets blocked, the ef
95 °F D.B. / 71 °F W.B.67 °F D.B. / 57 °F W.B.1. OPERATING RANGEMaximumMinimum115 °F D.B.67 °F D.B.Temperature Indoor Air Intake Temp. Outdoor Air In
15TROUBLESHOOTINGIf your air conditioner does not work properly, first check the following points before requesting service. If it still does not work
INSTALLATION INSTRUCTIONSXMS0972 & PNR-XS1872XMS1272 & PNR-XS1872XS1872 & PNR-XS1872(II-852-6-4190-494-00-0)APPENDIX CA-3
Model CombinationsCombine indoor and outdoor units only as listedbelow.Indoor Unit Outdoor UnitXMS0972 CM1972XMS1272 CM2472XS1872 CM3172Power Source:6
2IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or service person, it
3 Printed on container boxFor unit & PVCtube connectionFor drain hoseconnectionRemarksQ'tyFor full-scaleinstallationdiagram1244421For tempora
41-5. Additional Materials Required for Installation1. Refrigeration (armored) tape2. Insulated staples or clamps for connecting wire(See local codes.
5G Install the indoor unit more than 3.3' (1 m) away from anyantenna or power lines or connecting wires used for tele-vision, radio, telephone, s
6Hole-in-anchorConcrete InsertSuspension bolt (M10 or 3/8")Hole-in-plug(locally purchased)Fig. 6-123-5/8"(600mm)21-1/32"(534mm)Ceiling
7G In cases where it is necessary to raise the height of thedrain piping, the drain piping can be raised to a maximumheight of 2.78 ft. (850 mm) above
8Amust be within the range of 1/2"(13mm) to 23/32"(18mm). (Fig. 6-11)If not within this range, malfunction or other trouble may occur.Ceilin
2. SPECIFICATIONS2-1. Unit SpecificationsIndoor Unit XMS0972 & PNR-XS18722-1-1.VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerant0.1169,0002.65C
9(2) Removing the corner cover andindicator covera) While lightly pressing the cen-ter of the corner cover, pull upthe tab for the screw hole. Usethe
10Fig. 6-23Fig. 6-24 Fig. 6-25fit into the holes in the ceiling panel.Place the corner cover so that the 3 tabsThen fasten it in place with the suppli
113-6-5. Checking After InstallationG Check that there are no gaps between the unit and the ceiling panel, or between the ceiling panel and the ceilin
12When connecting each power wire to the correspondingterminal, follow the instructions “How to connect wiringto the terminal” and fasten the wire sec
134. How to Test Run the Air ConditionerAfter turning on the power of the air conditioner, use theremote controller and follow the steps below to cond
145. Remote Control Unit Installation PositionThe remote control unit can be operated from either anon-fixed position or a wall-mounted position.To en
15ACL(Reset)button1HR.TIMERbuttonON/OFFoperationbuttonHIGH POWERbutton6. Address Switch6-1. Address Setting of the Remote Control UnitThe address can
167. Connecting a Home Automation DeviceThe HA (white) 4P terminal is located on the indoor unit PCB. If a HA device willbe used, connect it to this t
INSTRUCTION MANUALSTK-RCS-7TWSUA(OI-852-6-4181-139-00-0)APPENDIX DA-4
STK-RCS-7TWSUA© SANYO 2009Pub. OI-85264181139000INSTRUCTION MANUALWired Remote ControllerMODE D’EMPLOITélécommande FilaireThis wired remote controller
Indoor Unit XMS0972 & PNR-XS1872VerticaldB-AIndoor : Hi/Me/LoAir FilterRefrigerantCooling208V Single-Phase 60Hz187 to 253Refrigerant Tubing Connec
2CONTENTSPagePRODUCT INFORMATION ...2ALER
3FEATURES• Microprocessor Controlled Operation• 24-Hour ON or OFF Timer• 1-Hour OFF Timer•Night Setback• Automatic and 3-step Fan Speed• Air Sweep Con
4REMOTE CONTROL UNITDisplayInformation on the operating conditions is displayed while the remote control unit is switched on. If the unit is turned of
5SensorA temperature sensor inside the remote control unit senses the room temperature.ON/OFF operation buttonThis button is for turning the air condi
6OPERATION WITH THE REMOTE CONTROL UNIT1. Automatic Operation(only for COOL/DRY/HEAT Model)• Single useThis unit automatically switches between coolin
73. Adjusting the Fan SpeedA. Automatic fan speedSimply set the FAN SPEED selector button to the position.This automatically sets the best fan spee
8SETTING THE TIMER1. How to set the present time(Example) To set to 9:10 pm. 2. How to set the OFF time(Example) To stop the air conditioner at 11:3
9USING THE 1-HOUR OFF TIMER1. 1-Hour OFF TimerThis function causes the unit to operate for one hour and then stop, regardless of whether the unit is o
INSTALLATION INSTRUCTIONSSTK-RCS-7TWSUA(OI-852-6-4190-481-00-1)APPENDIX EA-5
I Parts supplied with the remote controllerSee Table 1.I Remote controller installation guidelines• Mount the remote controller 3.3 to 4.9 ft. (1 to 1