Strona 1 - MDF-793AT

MDF-593MDF-593AT MDF-793 MDF-793AT Ultra Low Temperature FreezerINSTRUCTION MANUAL MDF-793AT MDF-593AT

Strona 2 - CONTENTS

9 ENVIRONMENTAL CONDITIONS This equipment is designed to be safe at least under the following conditions (based on the IEC 1010-1): 1. Indoor u

Strona 3

10 FREEZER COMPONENTS MDF-593 1313 7 81210114 296 5 1514

Strona 4

11 FREEZER COMPONENTS 1. Lock 2. Door: Hinged type. The door can be opened in any angle on the way to full open. 3. Magnetic door gasket

Strona 5

12 FREEZER COMPONENTS Control panel 1. Power switch (POWER): Power all functions except remote alarm and back-up system fo

Strona 6

13 Clean the condenser filter according to page 23 “Cleaning of condenser filter”. INSTALLATION Installation site To operate this unit proper

Strona 7

14 INSTALLATION Installation 1. Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the d

Strona 8 - CAUTIONS FOR USAGE

15 START-UP OF UNIT Follow the procedures for the initial and consequent operations of the unit. 1. Make sure that all the switches on the cont

Strona 9

16 OPERATING INSTRUCTIONS Temperature setting Table 1 shows the basic operation method. Perform key operations in the sequence indicated in

Strona 10 - ENVIRONMENTAL CONDITIONS

17 OPERATING INSTRUCTIONS Alarm temperature setting This unit is provided with the high temperature alarm. The setting of high temperature

Strona 11 - FREEZER COMPONENTS

18 OPERATING INSTRUCTIONS Setting of alarm resume time The alarm buzzer is silenced by pressing BUZZER key on the control panel during alar

Strona 12

1 Note: 1. No part of this manual may be reproduced in any form without the expressed written permission of SANYO. 2. The contents of this manual

Strona 13

19 OPERATING INSTRUCTIONS Alarm and safety functions This unit has the alarm and safety functions shown in table below, and also self diagn

Strona 14 - INSTALLATION

20 OPERATING INSTRUCTIONS Back-up system WARNING As with any equipment that uses CO2 gas, there is a likelihood of oxygen depletion in the

Strona 15

21 because of cooling capacity.) TEMPERATURE RECORDER The figure below shows the description of a temperature recorder. The temperature recorde

Strona 16 - START-UP OF UNIT

22 TEMPERATURE RECORDER Setting of back-up temperature 1. There is a red guide on the top of the temperature displayer. Adjust the guide with y

Strona 17 - OPERATING INSTRUCTIONS

23 ROUTINE MAINTENANCE WARNING Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in order to prevent

Strona 18

24 TROUBLE SHOOTING If the unit malfunctions, check out the following before calling for service, after transferring all the contents to another

Strona 19

25 DISPOSAL OF UNIT WARNING If the unit is to be stored unused in an unsupervised area for an extended period ensure that children do not have a

Strona 20

26 RECYCLE OF NICKEL-CADMIUM BATTERY The unit contains a rechargeable battery. The battery is recyclable. At the end of it’s useful

Strona 21

27 SPECIFICATIONS Name Ultra-Low Temperature Freezer Model MDF-593/MDF-593AT MDF-793/MDF-793AT External dimensions W2010 x D770 x H1070 (mm)

Strona 22 - TEMPERATURE RECORDER

28 CAUTION Please fill in this form before servicing. Hand over this form to the service engineer to keep for his and your safety. Safety ch

Strona 23

2 PRECAUTIONS FOR SAFE OPERATION It is imperative that the user complies with this manual as it contains important safety advice. Items and proc

Strona 24 - ROUTINE MAINTENANCE

Recycled paper SANYO Electric Biomedical Co., Ltd.10-15, Hongo 3-Chome Bunkyoku, Tokyo 113-8434 Japan P

Strona 25 - TROUBLE SHOOTING

3 PRECAUTIONS FOR SAFE OPERATION Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to rain

Strona 26 - DISPOSAL OF UNIT

4 PRECAUTIONS FOR SAFE OPERATION Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance.

Strona 27

5 PRECAUTIONS FOR SAFE OPERATION Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping. I

Strona 28 - PERFORMANCE

6 PRECAUTIONS FOR SAFE OPERATION Do not touch the condenser directly when the filter is removed for cleaning. This may cause injury by hot s

Strona 29 - Safety check sheet

7 CAUTIONS FOR USAGE ■ Always use a dedicated power source. The power source of this freezer is single phase and local voltage. The power sour

Strona 30 - 10-15, Hongo 3-Chome

8 CAUTIONS FOR USAGE ■ This unit is provided with the filter check lamp. If the filter check lamp is flashed, clean the condenser filter. Re

Komentarze do niniejszej Instrukcji

Brak uwag