SETTINGS FOR RS485 TERMINALS USE
The VCR can be controlled through a special controller
connected to the RS485 terminal.
If the VCR is going to be controlled trough a connection to
the RS485 terminals, be sure to first make the settings
below.
1 Press the MENU button until the (SET UP 5) menu is
displayed.
@@@@@@@<SET@UP@5>
öTAPE@END@OUT@@@@-3M
öWARN.@OUT@@@@@TRANSPORT
öRS485
@ADDRESS@@@@@@@@@000
@TERMINATE@@@@@@@N
@DATA@SPEED@@@@@@19200
@STATUS@INFO@@@@@Y
@ALARM@INFO@@@@@@Y
2 Press the ] button, until the “ADDRESS” setting is
flashing.
3 Press the l (or j) button to set the VCR address.
NOTES:
The address can be set between 000 and 127.
Keep the button pressed and the setting will
change rapidly.
4 Press the ] button, until the “TERMINATE” setting is
flashing.
5 Press the l (or j) button to set the termination.
N . . . . . . . . . . Not terminated
Y . . . . . . . . . . Terminated
6 Press the ] button, until the “DATA SPEED” setting
is flashing.
7 Press the l (or j) button to set the data transfer
speed.
8 Press the ] button, until the “STATUS INFO” setting
is flashing.
9 Press the l (or j) button to set the desired setting.
Y. . . . . . . . . . . The VCR status information (state
information and warning state)
and mode changes are output at
the RS485 terminal.
N. . . . . . . . . . . The VCR status information (state
information and warning state)
and mode changes are not output
at the RS485 terminal.
NOTE:
The warning state information output (sent) will
depend on the settings for WARN. OUT in the
(SETUP 5) menu.
F Press the ] button, until the “ALARM INFO” setting is
flashing.
G Press the l (or j) button to set the desired setting.
Y. . . . . . . . . . . The VCR alarm information
(alarm recording start and stop)
and video loss information are
output at the RS485 terminal.
N. . . . . . . . . . . The VCR alarm information
(alarm recording start and stop)
and video loss information are not
output at the RS485 terminal.
H Press the PAUSE/SEARCH button to save the
settings.
2400 4800 960019200